voc sensor thermokon

Thermokon | Forest Rock

Connection for external cable sensor for change over . ... Thermokon NOVOS 7 CO2+VOC Temp_rH RS485 room controller. Room controllers, Thermokon NOVOS 7 CO2+VOC Temp_rH RS485 room controller. 0 out of 5 (0) 735094. Room operating unit CO2 + VOC + temperature + humidity – BUS.

Get Price

Chat With WhatsApp

NOVOS 5 CO2+VOC • Thermokon

Room sensor in the NOVOS design for measuring CO2, mixed gas (VOC), temperature and humidity (relative, absolute, enthalpy, dew point) and displaying measured values through an integrated LCD with traffic light indication. The maintenance-free sensor forms the basis for a …

Get Price

Chat With WhatsApp

LK+ CO2+VOC VV • Thermokon

Aug 17, 2020 · Duct sensor CO2 + VOC or mix – active 2x 0..10 V. Measuring range CO2: 0..2000 ppm | 0..5000 ppm, configurable via Thermokon USEapp. Measuring dual channel, Accuracy CO2: ±50 ppm + 3% of measuring value (typ. at 21 °C and 50% rH) Impact- and shock-resistant enclosure USE-M with quick-release cover (PC, pure white, IP65) Removable cable ...

Get Price

Chat With WhatsApp

LK+ CO2+VOC VV • Thermokon

Aug 17, 2020 · Duct sensor CO2 + VOC or mix – active 2x 0..10 V. Power supply: 15..35 V = or 19..29 V ~. Output: 2x 0..10 V or 0..5 V (adjustable via jumper) Measuring range CO2: 0..2000 ppm | 0..5000 ppm, configurable via Thermokon USEapp. Measuring dual channel, Accuracy CO2: ±50 ppm + 3% of measuring value (typ. at 21 °C and 50% rH)

Get Price

Chat With WhatsApp

VOC Sensor SGP40 | Sensirion

Sensirion’s SGP40 is a broad-band VOC sensor which reliably detects high-VOC events. When built into an air quality monitor, it allows users to identify the sources of such events and take appropriate action. Integrated into smart air treatment devices, it enables automatic, demand-controlled operation. Sensirion’s powerful VOC Algorithm ...

Get Price

Chat With WhatsApp

LK+ CO2+VOC LCD Temp 3xV • Thermokon

LK+ CO2+VOC LCD Temp 3xV. Duct sensor CO2 + VOC or mix + temperature – active 3x 0..10 V. Power supply: 15..35 V = or 19..29 V ~. Output: 3x 0..10 V or 0..5 V (adjustable via jumper) Measuring range CO2: 0..2000 ppm | 0..5000 ppm, configurable via Thermokon USEapp.

Get Price

Chat With WhatsApp

Room Sensors • Thermokon

Room Air Quality Sensor (VOC) NOVOS move. Room Air Quality Sensor with LCD (CO2+VOC) WRF04 CO2. Surface Mount Room Air Quality Sensor CO2 . LC-WRF04 CO2. Surface Mount Room Air Quality Sensor (CO2) WRF06 AQ. ... Thermokon Sensortechnik GmbH Platanenweg 1 35756 Mittenaar

Get Price

Chat With WhatsApp

LK+ CO2+VOC VV • Thermokon

Aug 17, 2020 · Duct sensor CO2 + VOC or mix – active 2x 0..10 V. Measuring range CO2: 0..2000 ppm | 0..5000 ppm, configurable via Thermokon USEapp. Measuring dual channel, Accuracy CO2: ±50 ppm + 3% of measuring value (typ. at 21 °C and 50% rH) Impact- and shock-resistant enclosure USE-M with quick-release cover (PC, pure white, IP65) Removable cable ...

Get Price

Chat With WhatsApp

LA+ VOC Temp_rH 3xV • Thermokon

Aug 17, 2020 · Outdoor sensor VOC + temperature + humidity – active 3x 0..10 V . Power supply: 15..35 V = or 19..29 V ~ Output: 3x 0..10 V or 0..5 V (adjustable via jumper) ... Offset calibration via Thermokon USEapp. 2x pressure compensation element. Impact- and shock-resistant enclosure USE-M with quick-release cover (PC, pure white, IP65)

Get Price

Chat With WhatsApp

VOC Sensors - Belimo

VOC sensors are not stable in the long term and drift after some time. Most VOC sensors compensate for this by evaluating the lowest measuring value over a period of time as "clean air" and then correcting the zero point if necessary (baseline correction). Sample control VOC sensors …

Get Price

Chat With WhatsApp

Professional gas sensing solution supplier with over 30-year gas sensor manufacturing experience Contact Us